The ‘Basic Configuration Wizard’ is shown on your screen. Here you can select the configuration for your
unit. The following options are available:
JBOD : The harddisks inside the unit are configured as single disks. You will have 2 volumes.
SAFE (RAID 1) : The harddisks inside the unit are configured as a mirror configuration.
You will have 1 volume with the size of the smallest HDD. The other HDD will be a
duplication of the 1
st
harddisk.
BIG : The harddisks inside the unit are configured as 1 drive with a total storage capacity of
both HDD's.
SAFE33 : The harddisks inside the unit are partially configured as mirror configuration (33%).
The remaining capacity is configured as BIG volume.
SAFE50 : The harddisks inside the unit are partially configured as mirror configuration (50%).
The remaining capacity is configured as BIG volume.
FAST (RAID 0) : The harddisks inside the unit are configured as 1 drive with a total storage capacity of
2 times the size of the smallest HDD.
Note :
Some RAID explanations have different descriptions for JBOD and BIG volumes. In the Steelvine
Manager software, the above configuration explanations are valid.